Add to Favorites
Share

XGN15-12 AC Metal-Clad Enclosed Ring Main Unit

  • Description
Product Detail

    Dscription
    The type of the XGN15-12 switchgear is a portable and flexible gas insulated switchgear . Simple structure, flexible operation, reliable interlocking, combined with modular design and the back pressure relief channel setting, make the switch cabinet more safety and reliable.

    Product features
    XGN15-12 AC high voltage metal-enclosed ring main unit is the latest generation of SF6 as insulating, suitable for power distribution automation, offering a compact and expanded metal-enclosed switchgear, with simple structure, reliable operation, interlock, easy installation, on a variety of different applications, different user requirements, are able to provide a satisfactory technical solution. Voltage/current sensing technologies and newest protective device used, coupled with advanced technical performance and flexible method of Assembly, makes switchgear for running demanding hospital and airport, still capable of freely, fully meet the changing demands of the market.

    The high voltage of XGN15-12 RMU is mainly used for the FLN36/FLN38 type of the SF6 load break switch, Schneider SC6, AS-12 series load break switch and the ABB original SFG type load break switch, GN30 type disconnecting switch. It also can be assembled with VS1 circuit breaker, ABB original VD4 circuit breaker or other fixed type circuit breaker, according to customer’s requirements. 


    Comply with Standard
    This product complies with standards GB3804?3906?11022
    IEC298?265?129?694?420?56?529?932

    Application field 
    XGN15-12 AC high voltage metal-enclosed ring main unit applicable to the exchange of 50HZ, 10/24kV of the power system, widely used in industrial and civil cable loop and power supply terminal. Particularly applies to the following sites: urban residential distribution and small secondary substations and switching stations, factories, shopping malls, airports, subway, wind power, small and medium power plants, hospitals, stadiums, railways, tunnels and so on protection of electrical equipment and control purposes.


    Work conditions
    A.Altitude: ?1000m

    B.Ambient temperature:-25?C~+45?C
    C.Relative humidity: daily average relative humidity is not more than 90%
                  monthly average relative humidity is not more than 90%

    D.Earthquake intensity: ?8 degree

    E.There is no violent vibration and impact, as well as fire, explosion, chemical corrosion dangerous places.


    Technical parameter and size

    rated voltage 
    KV12
    rated lightning impulse withsttand voltageph-ph,ph-groundKV75
    breaker gapKV85
    1min power frequency withstand voltage ph-ph,ph-groundKV42
    breaker gapKV48
    rated frequence
    HZ50/60
    rated currentmain busbarA1250
    branch busbarA1250
    rated short time withstand currentmain loopKA20/3s
    branch loopKA20/2s
    rated peak withstand current
    KA50
    transformer current
    A1700
    protection class

    IP3X
    load switch mechanical life 
    times2000
    earth switch mechnical life
    times2000
    load switch cabinet deepmm916,940,840
    widemm375,500,750
    highmm1635,1885,1600,1800
    low pressure chamberhighmm350,450
    circuit breaker cabinetdeepmm650,750,800
    widemm916,940,840
    highmm1885,1800,2100